Industries We Serve
PITSA has built fiberglass reinforced plastic equipment since 1965, and the same four products — tanks, pipes, ducts and grating — end up doing very different jobs depending on the plant they go into.
What changes between industries is not the catalogue. It is the resin, the design case, and the failure everyone is trying to avoid. A tank for sodium hypochlorite and a tank for brine are the same shape and a different product.
These pages set out what each industry actually needs, so that a specification arrives with the answers that change the design.
The industries
- Mining — abrasion as well as corrosion. Slurry lines, leach and thickener equipment, and process water in remote sites where replacing steel is expensive twice over.
- Chemical processing — the hardest chemistry, and where dual-laminate construction earns its place.
- Water and wastewater — hypochlorite storage, odour control, and decades of service life on a public budget.
- Petrochemical — where chlorides defeat stainless steel, and what ISO 14692 and flame-spread requirements change.
- Agrochemical and fertilizer — where the mistake is almost never the chemistry, it is the specific gravity.
- Food and beverage — where the cleaning cycle, not the product, decides the resin.
- Pharmaceutical — demineralized water that is more aggressive than it looks, and documentation that must survive an audit.
- Construction and infrastructure — chosen for what it is not: conductive, magnetic, or something you have to recoat.
- Automotive and surface treatment — hot acid and alkaline baths, and the extraction duct that fails before the tank.
What every industry gets asked
Whichever plant you are in, the same short list decides the design:
- The chemical, and its concentration. Not the category — the chemical.
- Temperature, operating and maximum excursion. Chemical resistance falls as temperature rises.
- Specific gravity of the contents, which sets the structural load.
- Pressure, and — most often missing — whether the equipment can see vacuum.
- Site location, for seismic and wind loading.
Why the plant matters as much as the chemical
Two plants storing the same acid can need different equipment, because the things around it differ: how often it is emptied, whether the line is heated, whether an operator can reach the vent, whether the site is coastal, whether a crane can reach the foundation.
Our engineering department designs from the process conditions rather than from a catalogue number, and uses finite element analysis where the geometry or the loading is unusual.
Contact a sales engineer
Choose your preferred contact method