FRP for Chemical Processing

This is the industry FRP was developed for, and the one where the choice of resin decides everything. The structure of a chemical storage tank is straightforward engineering. The corrosion barrier is where the job is won or lost.

The specification that is not a specification

"FRP tank, 30 m³, vinyl ester" looks like a specification. It is not, because it does not say:

  • Which chemical, at what concentration. Sulphuric acid at 10% and at 93% are different design problems, and a resin that suits one can fail in the other.
  • The temperature, and the excursion temperature. Chemical resistance falls as temperature rises. A resin comfortable at 60 °C may be unsuitable at 90 °C in the same chemical.
  • What else is in there. Traces of an oxidiser or a solvent can rule out a resin that the main chemical alone would allow.

Send the process conditions and let the resin be selected from them. A resin named without the conditions behind it is a guess someone else made.

When FRP alone is not enough: dual-laminate

Some chemistry defeats every thermoset resin — hot concentrated acids, strong oxidisers, certain solvents, and mixed streams whose components would each be manageable alone.

For those, PITSA builds dual-laminate equipment: a thermoplastic liner of PVC, PE, PP or PVDF that does the chemical work, structurally backed by FRP that carries the load. Each material does what it is good at.

We have built dual-laminate equipment since 1980. It costs more than FRP alone, and it is the correct answer when the service demands it.

Codes

Atmospheric tanks are designed to ASTM D3299. Pressurised and vacuum equipment is designed to ASME RTP-1, up to 15 psig internal and external. Whichever applies, our internal quality system follows ASME RTP-1 on every project, including projects that do not require it.

For complex or critical geometry we run finite element analysis before fabrication, rather than after a problem.

Typical equipment

Storage and day tanks, reaction and mixing vessels, scrubbers and fume hoods, process and transfer piping, ducting for acid vapour, stacks, and grating for bunded areas where a spill is expected rather than hoped against.

The vent, in this industry especially

An atmospheric tank is designed for zero gauge pressure, and its vent is what keeps it there. Crystallising chemicals block vents — that is the ordinary case, not the unlucky one.

A blocked vent during pump-out implodes the tank, and FRP is far weaker in external pressure than internal, so that is the failure that arrives first. Size the vent for the maximum fill and discharge rate, keep it clear, and inspect it on a schedule.

Contact a sales engineer

Choose your preferred contact method

Posted on • by PITSA FRP